Solaris firmware upgrade procedure

05.11.2020

You can download the firmware from oracle support website. Here we can take the current configuration backup. Enter passphrase as some numbers and you need to supply this numbers during the configuration restore.

Once you have done,just click on run to save the configuration. Click on the browse and provide the complete path of firmware file which you have downloaded from oracle support website.

Check Preserve Existing configuration is enabled or not. If not enabledselect the check bios. You will get the below notification saying that SP will restart. Try to reconnect after 5 to 10 minutes to get the ilom console back. Once you got the ILOM console back, you can login and check the firmware version. You can see newer version of firmware will be updated.

You can also use the same procedure for SUN chassis firmware upgrade as well and you no need to halt the blades for chassis upgrade.

Your email address will not be published.

Facebook loq in

Currently you have JavaScript disabled. In order to post comments, please make sure JavaScript and Cookies are enabled, and reload the page. Click here for instructions on how to enable JavaScript in your browser.

Related Articles.

How to Upgrade ilom firmware on oracle sun servers ?

Leave a Reply Cancel reply Your email address will not be published. Sun Server X Sun Blade Modular System. Sun Server XL.Manage your account and access personalized content. Sign up for an Oracle Account. Access your cloud dashboard, manage orders, and more.

Sign up for a free trial. Oracle Server product patches, updates and firmware are now available on My Oracle Supportfrom the Patches and Updates tab. If, on the Download Information Page, you get the message "You do not have permissions to download this Patch Note: This list of Oracle Server Systems is not comprehensive. It contains only the most recently available systems. You can use My Oracle Support to manually search for downloads for older systems by using the steps listed above. Additional information about updating your firmware can be found on the Firmware Resources page.

Latest Version Is Highlighted. Sun System Firmware 9. SysFW 9. Fallback Boot based on Solaris Fallback Boot HW Programmables 1. Fujitsu M Server. XCP download Nov XCP download Jul XCP download Mar XCP download Sep XCP download Apr XCP download Jan XCP download May Fujitsu MS Server. XCP download Oct XCP download Aug SysFW 8. SysFW 7.

Sun Blade T Server Module. Sun Netra T Server. Sun Fire T Server. XCP download Feb Netra Modular System. NMS Software 1. Oracle Server XM Software 1. Sun Blade Chassis. CMM Software 4. Chassis 4.Post a Comment.

Seaborn barplot order

When upgrading an M, the controllers switch roles: active becomes standby, and vice-versa. At the end you will be connected to the standby controller. The firmware upgrade is performed first on the XSCF Unit on the standby side and then on the active side automatically. Therefore, the user must log in again. Check current firmware level: version -c xcp.

Reera spa dhaka

XSCF 0 Active. XCP0 Reserve : XCP1 Current : The XCP version number appears as xyyz by four digits, where:. Check version of staged firmware: getflashimage -l. Existing versions:. Note: In case of web server, we can also use FTP server.

MD5: fbd0d47d6faddfd Warning: About to delete existing versions. Free space: 93MB. Download successful: Kbytes in 50 secs Checking file MD5: eff68bbb7afe. Use the flashupdate command with the "check" argument to determine ability to update to the new firmware version.

XCP update is possible with domains up. The XSCF will be reset. Checking the XCP image file, please wait a minute. XSCF is rebooting to update the reserve bank. XSCF reset. The system is g. Please stand by while rebooting the system. Restarting system.

Deca for joints

DDR: MB. Booting image at ff Load Address: Verifying Checksum Uncompressing Kernel Image Loading Ramdisk to 0ba9a, end 0bfff Linux version 2.

Built 1 zonelists. OpenPIC Version 1. PID hash table entries: order: 10, bytes. Dentry cache hash table entries: order: 5, bytes. Inode-cache hash table entries: order: 4, bytes.To perform this procedure, become an administrator that provides solaris.

Note the device groups, the resource groups, and the node list for the resource groups. This process might require you to boot into noncluster mode. If it does, boot the node into cluster mode before proceeding. For the procedure about how to upgrade your transport adapter firmware, see the patch documentation.

In these commands, devicegroup is one or more device groups that are returned to the node. For failover resource groups, the node to which the groups are returned. For scalable resource groups, the node list to which the groups are returned. Exit Print View. Search Scope:. This Document Entire Library. How to Upgrade Transport Adapter Firmware You might perform this procedure in the following scenarios: You want to use firmware bug fixes. You want to use new firmware features.

Use this procedure to update transport adapter firmware. Before You Begin To perform this procedure, become an administrator that provides solaris. Determine the resource groups and the device groups that are online on the node. This node is the node where you are upgrading transport adapter firmware. Use the following command: clresourcegroup status -n nodename cldevicegroup status -n nodename Note the device groups, the resource groups, and the node list for the resource groups.

Migrate the resource groups and device groups off the node on which you plan to upgrade the firmware. Perform the following step for each device group you want to return to the original node. Perform the following step for each resource group you want to return to the original node. All rights reserved.Solaris Live Upgrade greatly simplifies the upgrade and patching process.

Patching the copy of your system provides these advantages:. Depending on the patch properties of the patch that is applied, a reboot might be required before further patches can be applied. Or, the system might require that you apply patches in single-user mode. Solaris Live Upgrade avoids having to reboot or take the system down to single-user mode. Solaris Live Upgrade reduces the amount of downtime involved in patching and reduces risk by providing fallback capability if necessary.

Then you patch the copy that you created, rather than patching the running system. When you are ready to activate the changes, you boot the copy, and the copy becomes the active OS.

How To Use Solaris Live Upgrade to Install Patches

This enables the currently running system to continue to run throughout the patching process. If problems occur with the newly patched copy, you can fall back to the original OS.

All tasks except the reboot can be accomplished on an operational production system, so the impact on any running processes is minimal. The combination of maximizing system availability when applying changes and minimizing risk by offering the ability to reboot to a known working state your original boot environment has made Solaris Live Upgrade a tool of choice for the data center since the Solaris 8 release.

This document provides a high-level procedure for doing a simple patching process. For links to more documentation. If you are using Solaris Live Upgrade from another release, you might need slightly different procedures. For your specific release, see the Solaris Live Upgrade documentation on docs.

Creating a new boot environment with the lucreate command. Applying patches to the new boot environment with the luupgrade command. Using the luactivate command to activate the new boot environment or fallback to the original boot environment.

Removing an inactive boot environment with the ludelete command. You can remove a boot environment after the running boot environment is stable. You need to upgrade to the latest version of the Solaris Live Upgrade software prior to patching the system, regardless of the version of the Solaris OS running on the system.

The procedure below shows you how to add the latest packages. You need these for the latest features and bug fixes.

For the release you are using, see the Solaris Live Upgrade documentation on docs. Separate multiple patch names with a space. Note - The patches need to be applied in a specific order that are specified in infodoc These packages include existing software, new features, and bug fixes. If you do not remove the existing packages and install the new packages on your system before using Solaris Live Upgrade, upgrading to the target release fails.

If you are using Solaris Live Upgrade packages from a previous release, you do not need to remove this package. The following provide the steps to install the packages by using the liveupgrade20 command. The liveupgrade20 command requires Java. If your system does not have Java installed, then you need to use the pkgadd command to install the packages individually.

The -noconsole and -nodisplay options prevent the character user interface CUI from displaying.Perform this procedure on each node in the cluster to upgrade the Solaris OS. Perform all steps from the global zone only. The cluster must already run on, or be upgraded to, at least the minimum required level of the Solaris OS to support upgrade to Sun Cluster 3.

If you are performing a dual-partition upgrade, the node must be a member of the partition that is in noncluster mode. Determine whether the following Apache run-control scripts exist and are enabled or disabled:. If these scripts exist and contain an uppercase K or S in the file name, the scripts are enabled.

No further action is necessary for these scripts. If these scripts exist but the file names contain a lowercase k or sthe scripts are disabled. Entries for globally mounted file systems contain the global mount option. Comment out these entries to prevent the Solaris upgrade from attempting to mount the global devices. Any Solaris upgrade method except the Live Upgrade method. Do not perform the final reboot instruction in the Solaris software upgrade.

Instead, do the following:. When you are instructed to reboot a node during the upgrade process, always reboot into noncluster mode. For the boot and reboot commands, add the -x option to the command.

The -x option ensures that the node reboots into noncluster mode. For example, either of the following two commands boot a node into single-user noncluster mode:. In the GRUB menu, use the arrow keys to select the appropriate Solaris entry and type e to edit its commands. In the boot parameters screen, use the arrow keys to select the kernel entry and type e to edit the entry.

Firmware upgrade procedure for Fujifilm button operation type cameras

This change to the kernel boot parameter command does not persist over the system boot. The next time you reboot the node, it will boot into cluster mode. To boot into noncluster mode instead, perform these steps to again to add the -x option to the kernel boot parameter command. If Apache run control scripts were disabled or did not exist before you upgraded the Solaris OS, ensure that any scripts that were installed during Solaris upgrade are disabled.

To disable Apache run control scripts, use the following commands to rename the files with a lowercase k or s. Alternatively, you can rename the scripts to be consistent with your normal administration practices.

When the VxVM procedures instruct you to perform a final reconfiguration reboot, do not use the -r option alone. Instead, reboot into noncluster mode by using the -rx options. If you see a message similar to the following, type the root password to continue upgrade processing. Do not run the fsck command nor type Ctrl-D. Install any required Solaris software patches and hardware-related patches, and download any needed firmware that is contained in the hardware patches.

Do not reboot after you add patches. Wait to reboot the node until after you upgrade the Sun Cluster software. Upgrade to Sun Cluster 3.This chapter includes the following sections:. Review these cautions and these guidelines when updating the firmware. Log in as any user with Administrator privileges.

solaris firmware upgrade procedure

When the firmware update is complete, the system automatically reboots. You can view ILOM version information using either of the following methods:. Establish an SSH connection using the following command:. Enter the default password when you are prompted:.

solaris firmware upgrade procedure

After you have successfully logged in, the SP displays its default command prompt:. Type the version command, which returns output similar to the following:.

SP firmware version: 2. SP firmware build number: SP filesystem version: 0.

solaris firmware upgrade procedure

Configure your terminal device or the terminal emulation software running on a laptop or PC to the following settings:. If needed, connect a dongle cable to the server module.

This will be different for each server. The ILOM firmware version and build number are listed above. Log in to the ILOM web interface.

The current firmware version information appears. The procedure to download the new firmware image differs between xbased systems and SPARC-based systems. Follow the procedure below that applies to your platform. Download the flash image. Select the Platform and Language for your download.

If you do not have a Username and Password, you can register free of charge by clicking Register Now. Click the appropriate firmware image file name:. Click Accept to accept the License Agreement. Select the latest firmware update for your server. Confirm your choice by clicking on the associated Readme link and read the patch update information.

Click HTTP to download the zip file package. Put the zip package on a TFTP server that is accessible from your network. At the prompt for confirming that you want to load the specified file, type y for yes or n for no. At the preserve configuration prompt, type y for yes or n for n. The system loads the specified firmware file then automatically reboots to complete the firware update.

Verify that the proper firmware version was installed.